Retentissement de l’épaisseur de l’os cortical sur la stabilité des mini-vis orthodontiques
Incidence of cortical bone thickness on the orthodontic miniscrew stability
Adresse de correspondance : Département d’Orthodontie et d’Orthopédie DentoFaciale,
Clinique Universitaire d’Odontologie, Faculté de Médecine, Université d’Oviedo,
C/Catedrático Serrano s/n 33006 Oviedo, Asturias Espagne
Résumé
Nous avons comparé le comportement de trois mini-vis de 10 mm de longueur, d’utilisation courante en orthodontie, dans quatre situations présentant un os cortical différent. Nous avons utilisé l’analyse des éléments finis (FEM) en appliquant une force de 250 g dans deux directions, l’une perpendiculaire et l’autre parallèle à la surface de l’os.
L’objet de cette étude portant sur la variable constituée par l’épaisseur de l’os cortical, quatre simulations de perte osseuse différentes ont été utilisées : 2,5 mm, 2,0 mm, 1,5 mm et 1 mm. Les tensions et les déplacements engendrés par l’application d’une force de 250 g, perpendiculaire puis parallèle à la surface osseuse, ont été évalués dans les mêmes conditions. Les résultats montrent un comportement similaire des trois mini-vis étudiées avec une augmentation des tensions et des déplacements de l’os environnant, pour des variations semblables d’épaisseur de l’os cortical.
Abstract
We compared the performance of three miniscrews 10 mm in length, currently used by orthodontists, in four situations where a different cortical bone thickness was presented. We used the Finite Element analysis Method (FEM) by applying a force of 250 g in two directions, one perpendicular and the other parallel to the surface of the bone.
The goal of this study concerned the variable represented by the thickness of the cortical bone, four simulations with different bone loss were utilized: 2.5 mm, 2.0 mm, 1.5 mm, 1 mm. The tensions and movements achieved by a force of 250 g, perpendicular and then parallel to the bony surface, were evaluated under the same conditions. The results demonstrate a similar performance of the three mini- screws that were studied by increasing the tensions and movements on the surrounding bone, with similar variations for the thickness of the cortical bone.
Mots clés : Mini-vis / Os cortical / Ancrage squelettique / Os trabéculaire
Key words: Miniscrews / Skeletal anchorage / Cortical bone / Trabecular bone